Wien, Volksoper
Redevelopment in two phases 2012 and 2013
New electronic stage control system TTS EMS IV according to IEC 6150
- 54 drives for hydraulic prospect hiss, nominal load capacity 350 kgs, vmax = 1.2 m/s
- 1 drive for acoustic curtain, nominal load capacity 1,000 kga, vmax = 1.2 m/s
- 8 point hoists, nominal load capacity 400 kgs each, vmax = 1.2 m/s
- 2 electric drives for hydraulic heavy duty winches, nominal load capacity 700 kgs each, vmax = 0.6m/s
- 1 lightning truss, nominal load capacity 1,200 kgs, vmax = 0.3 m/s
- 3 electric drives for horizontal winches, nominal load capacity 400kgs each, vmax = 0.8 m/s
- 1 electric drives for hydraulic horizontal lightning winch, nominal load capacity 800 kgs each, vmax = 0.3 m/s
- 1 drive for lifting main curtain
- 1 drive for greek curtain
- 1 el. drive for proscenium bridge
- new drives for revolving stages (inner and outer ring)
- new drive for prompter cabin.